Why is my Reddy heater keep shutting off?

Why is my Reddy heater keep shutting off?

For air leaks at the pump or between the pump and nozzle. Check with soapy water. If the pressure is correct and the heater fires off & runs with the top cover off, but goes out when the lid is replaced, then it’s a 90% good bet that the nozzle is worn. Replace it.

Why is my Reddy heater not working?

Check for fuel problems if the motor runs, but the heater won’t ignite, or if you spot smoke or smell an odor coming from the unit. Clean the tank completely and refuel with the recommended fuel oil, kerosene or diesel if you spot water.

How do you check fuel pressure on a Reddy heater?

  1. Remove the plastic cover in the middle of the air intake side of the heater, with a flat-head screwdriver.
  2. Read the pressure gauge to see the air pressure of your Reddy Heater.
  3. Read the instructions that came with your Reddy Heater, to determine the correct air pressure.

Why does my Reddy Heater smoke?

Blow compressed air into the outlet end of the fuel nozzle if you suspect a clog, which could occur when the heater fails to ignite or you notice smoke or an odor. Replace the fuel nozzle completely if it appears damaged or defective.

Is there a problem with my Reddy heater?

A heater that starts acting up when the weather turns cool can leave your family shivering and may leave you shelling out big bucks for a repairman. Save money and get your Reddy heater running properly with some basic troubleshooting techniques, which can help you resolve many of the most common problems associated with these units.

How big of a room does a Reddy heater heat?

Reddy Heaters R60 – 60,000 Btu/Hr. R60 Heaters Heat up to 1600 sq. Ft. R60 Reddy Heaters were Manufactured by Desa prior to 2009. See DESA Owners manual for more specifications @ www.DesaTech.com

What should the air pump pressure be on a Reddy heater?

If the pump pressure is incorrect, then, the fuel delivery will be incorrect. As a result, the heater will not run to specs. Instructions for setting the air pump pressure: Air pump pressure is the pulse of the heater. Pump pressures range from 3 psi to 6 psi depending on heater BTU size (see chart below).

How big is a desa Reddy kerosene heater?

I have a Desa ‘Reddy Heater’ 60,000 BTU After being plugged to 120 elec. it starts after a few seconds as it should (and always had!) BUT … read more Journeyman Service Techni… State Licensed Mechanical… Have a Reddy Heater / R50/A 50,000 BTU the heater will start and run for about 20 to 30 seconds and cut off.

Why is my Reddy heater keep shutting off? For air leaks at the pump or between the pump and nozzle. Check with soapy water. If the pressure is correct and the heater fires off & runs with the top cover off, but goes out when the lid is replaced, then it’s a 90% good bet…